Installation of the WeR@Home™ System
156
WeR@Home
System User Guide
Figure 129: Smoke Detectors in Multi-floor House
t Install Smoke Detectors at both ends of a bedroom hallway if the hallway is longer than 12
meters (40 feet).
t Install basement Smoke Detectors at the bottom of the stairway as shown in Figure 129
above.
t Install the Smoke Detectors as close to the center of the ceiling as possible. If this is not
practical, install the Smoke Detector on the ceiling no less than 10 cm (4 inches) away
from any wall or corner.
t If ceiling mounting is not possible and wall mounting is allowed by your local and state
codes, mount the Smoke Detectors on a wall 10 to 15 cm (4 to 6 inches) from the ceiling.
t In rooms with sloped, peaked, or gabled ceilings, mount the Smoke Detectors 90 cm (3
feet) measured horizontally from the highest point of the ceiling.
t Nuisance alarms occur if Smoke Detectors are installed where they do not work properly.
To avoid nuisance alarms, do not install alarms in the following locations:
a) Areas where combustion particles are present (i.e. kitchens with few windows or
poor ventilation, garages where there may be vehicle exhaust), or near heaters, hot
water boilers, etc.
b) Less than 6 meters (20 feet) from places where combustion particles are present. If
such distance is not available (e.g., in mobile homes), install the alarm as far away
from the combustion particles as possible, preferably on the wall. Provide good
ventilation in such places.
c) Damp or humid areas. Moisture can enter the detection chamber. Upon cooling,